October 25, 2002 / 25 Octobre, 2002 1 Manual / Manuel 0-2951
Manual 0-2951
Torch Adapter Kit
Catalog # 7-3477
Installation Instructions
General Information
These instructions cover Thermal Dynamics RPT Adapter Kit No. 7-3477. The kit connects 1Torch SL60 or SL100
Torches equipped with O2B connectors, or the ATC Adapter Kit, to the following Power Supplies:
Hypertherm* powermax* 380
Miller* Spectrum* 375
Supplied Parts
The kit includes:
Gas Line Adapter Fitting with Gas Line
Power Wire Harness with Connector
Control Wire with Connector
Insulating Sleeve
Strain Relief
Instructions
WARNINGS
Disconnect primary input power to the system before starting the installation.
Shut off the gas supply and bleed down the system.
Only a qualified technician should perform this procedure.
Procedure
A. Preparation
1. Remove the Power Supply Cover per the Power Supply Manual.
2. Disconnect the original torch per the Power Supply Manual.
3. Disconnect the inductor wire connected to the terminal marked 'L2 RED' on the Power Supply circuit board.
4. Disassemble the Strain Relief provided in this kit.
5. Slide the Strain Relief dome nut (only) onto the Torch Leads or ATC Adapter Kit.
6. Fold back the shortest wire connector on the Torch Leads or ATC Adapter Kit.
7. Slide the Strain Relief over the Leads or Adapter fittings.
8. Straighten the short wire folded back previously.
82 Benning Street, West Lebanon, NH 03784 USA
(603) 298-5711 • www.thermal-dynamics.com
© 2002 Thermal Dynamics Corp., Tous droits réservés. Printed in USA . Imprimé dans É-U. *
HYPERTHERM and *
powermax are registered
trademarks of Hypertherm, Inc.
*
Miller and *
Spectrum are registered trademarks of Miller Electric Co., Inc.
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Procedure

October 25, 2002 / 25 Octobre, 2002 1 Manual / Manuel 0-2951Manual 0-2951Torch Adapter KitCatalog # 7-3477Installation InstructionsGeneral Information

Pagina 2 - B. Installation

October 25, 2002 / 25 Octobre, 2002 2 Manual / Manuel 0-2951B. Installation1. Pass the end of the leads or ATC Adapter through the torch leads opening

Pagina 3 - C. Operation

October 25, 2002 / 25 Octobre, 2002 3 Manual / Manuel 0-2951C. Operation1. Connect primary input power. Turn on the gas supply.2. Set proper gas pres

Pagina 4

October 25, 2002 / 25 Octobre, 2002 4 Manual / Manuel 0-2951

Pagina 5 - Catalogue # 7-3477

October 25, 2002 / 25 Octobre, 2002 5 Manual / Manuel 0-295182 Benning Street, West Lebanon, NH 03784 USA(603) 298-5711 • www.thermal-dynamics.comMa

Pagina 6

October 25, 2002 / 25 Octobre, 2002 6 Manual / Manuel 0-2951B. Installation1. Passage l’extrémité des fils ou de l’adapteur d’ATC par les fils de torc

Pagina 7 - C. Fonctionnement

October 25, 2002 / 25 Octobre, 2002 7 Manual / Manuel 0-2951C. Fonctionnement1. Connectez la puissance d’entrée primaire. Spire sur l’offre de gaz.2 P

Pagina 8

October 25, 2002 / 25 Octobre, 2002 8 Manual / Manuel 0-2951

Commenti su questo manuale

Nessun commento